How to use the vents to control too low humidity?

 Answer 

The picture below shows the greenhouse climate settings.



You can select the first 3 settings like this:


Here you see the 3 selected settings in 1 picture:



When the relative is too low you can decrease the vent position at the wind side.
You can do this by increasing the ventilation temperature at the wind side depending on the measured RH.
Start with this control after noon, so for example from 13.00 pm.

Add an influence of relative humidity to the setting "ventilation temperature wind side" and add an extra period like this:




    • Related Articles

    • EN - How to use the vents to control too high humidity

            Question How to use the vents to control humidity?  Answer  There is a special vent setting for humidity control: "lee side vent position: humidity". With this setting it is possible to open the vent a little bit when the relative humidity (RH) ...
    • EN - How to use the heating to control too high humidity

            Question How to use the heating to control too high humidity?  Answer  The setting for humidity control is: "circuit pipe minimum". With this setting it is possible to heat up the pipes when the relative humidity (RH) is too high or the ...
    • EN - How to use the vents to control too high CO2

            Question How to use the vents to control CO2?  Answer  The setting for CO2 control is: "lee side vent position minimum". With this setting it is possible to open the vent a little bit when the CO2, which is coming from the soil, is too high. ...
    • EN - How to close the vents before opening the screens to avoid cold fall

          Question How to close the vents before opening the screens to avoid cold fall?  Answer  Example 1 The screen is closed during the night as energy screen. The ventilation temperature can be increased as soon as the curtain is opening. This is done ...
    • EN - 025930 - How to use +PAR module?

      Question I have a PAR sensor in the greenhouse and the software module +PAR. How to use the +PAR module? Answer The iSii + PAR module is optional from version 3.3.3.1 or higher. With this module you can control the PAR value under the (partly) closed ...