IIVO - Determine base temperature and RTR

IIVO - Determine base temperature and RTR

1. Complete the excel sheet in the attachment

2. Select D4 to E45
3. Choose Insert and then the dot graph
4. Place the mouse on one of the dots and right click
5. Choose Add Trendline
6. Check "Show comparison in graph"
7. You now have the formula for the line. For example: y=0,0015x+19,485
    The target RTR is then 1,5 per 1000 J/cm²
    The base temperature is 19,5 °C


8. In IIVO you set this as follows:

    • Related Articles

    • IIVO - Bepaal basistemperatuur en RTR

      1. Vul de excel sheet in de bijlage in. Bijvoorbeeld 19,5 invullen met komma, niet met punt. 2. Selecteer D4 t/m E45 3. Kies Invoegen en dan de stippengrafiek 4. Ga met de muis op één van de stippen staan en klik rechts 5. Kies Trendlijn toevoegen 6. ...
    • IIVO - Bouwen visualisatie achtergrondplaat

      Een visualisatie in IIVO bestaat uit een achtergrondplaat waarop parameters worden gezet. Bovenstaande achtergrondplaat kan gemaakt worden met Microsoft Visio of met draw.io. Hoe gebruik je draw.io? Type draw.io in de adresregel van een browser. Kies ...
    • IIVO - Building visualization background picture

      A visualization in IIVO consists of a background picture on which parameters are set. The background picture above can be made with Microsoft Visio or with draw.io. How to use draw.io? Type draw.io into the address line of a browser. Then choose ...
    • IIVO - Troubleshooting Aspirator box

      Greenhouse temperature is not measured properly with a dry/wet bulb aspirator box At a distance (online) Carefully read the installation manual on the PartnerWiki Check whether real time values are received in I/O CONFIGURATION Check whether the ...
    • IIVO - Set up CO2 controls

      Configuration Below is a visualization of the CO2 configuration. CO2 can be supplied by the boiler or CHP5 or CHP6. Outside air can be mixed in. Industrial CO2 and liquid CO2 are injected. Connections Climate Required connections in climate: ...