EN - 642794 Silo pressure sensor First Sensor KTE/CTE-series

EN - 642794 Silo pressure sensor First Sensor KTE/CTE-series

  
This article is only for Hoogendoorn Partners

Question

How to install this sensor.

 Answer 

Take a look to the attached installation manual.

It is possible to use the temperature measurement of this silo pressure sensor. This method is not supported by Hoogendoorn.
In the delivery should be a silo pressure sensor and a special programmed transmitter with cable compensation and which is able to transform the PT1000 signal to a 4-20mA signal. Like the one on the picture bellow.



In this type of pressure sensors are two measurements inside.
1. Measure the pressure of the water column above the sensor with a 4-20mA signal.
2. Measure the water temperature with a PT1000 signal.


The pressure sensor can be linked in the software in different ways:
- as a level measurement
- as a silo measurement


Level measurement

The adjustment of the sensor is as follows:

1. Double-click Level tray



2. Select the level measurement that you want to calibrate
3. Click OK



4. Click on the Measure & Actuate tab
5. Open the setting "level tray water level: measurement (I/O)"




Place the sensor on the bottom of a bucket with 20 cm of water



6. Read the gross measurement
7. Enter this value in the "minimum gross measurement" setting




Place the sensor on the bottom of the filled silo



8. Read the gross measurement
9. Enter this value in the "maximum gross measurement" setting





Silo measurement

The adjustment of the sensor is as follows:

1. Double-click Silo



2. Select the silo measurement that you want to calibrate
3. Click OK



4. Click on the Measure & Actuate tab
5. Open the "level measurement" setting




Place the sensor on the bottom of a bucket with 20 cm of water



6. Read the gross measurement
7. Enter this value in the "minimum gross measurement" setting



Place the sensor on the bottom of the filled silo


8. Read the gross measurement
9. Enter this value in the "maximum gross measurement" setting

    • Related Articles

    • NL - 642794 Silo niveau sensor First Sensor KTE/CTE-series

         Dit artikel is speciaal geschreven voor Hoogendoorn Partners Vraag Hoe installeer je deze sensor.  Antwoord  Bekijk de bijgevoegde installatiehandleiding. Het is mogelijk om de temperatuurmeting van deze silodruksensor te gebruiken. Deze methode ...
    • EN - 023356 Silo management

         This article is only for Hoogendoorn Partners Question How silo management is working?  Answer  Please read the attached document.
    • EN - How to do maintenance on a pH sensor

             Question How to do maintenance on a pH sensor?  Answer  As you can see in the table below, you can clean the sensor with clean water. Watch the video below how to calibrate an pH sensor: The calibration procedure in steps: ​In this video we ...
    • EN - Vapor pressure difference in practice

      Source: Just4Growers Once you understand what vapor pressure difference is, all those environmental factors you're trying to juggle in your mind suddenly click into place and you start to think and feel like a plant. Take a few minutes to understand ...
    • NL - 023356 Silo management

         Dit artikel is geschreven voor Hoogendoorn Partners Vraag Hoe werkt silo management?  Antwoord  Lees het bijgevoegde document.