The picture below shows the recipes settings.
unit phase 2 supply
phase 2 supply time: ViP
The supply time is 3 minutes for every cycle.
EC control EC value: ViP
The EC value is set to 1.5
Example:
Decrease the EC value when we get more radiation. Because the plant needs more water than fertilizer when it is sunny.
pH control: pH value
The pH value is set to 5.5
fertilizer phase 2: number
The ferlizer number 1 is selected
interval: ViP
delay time: ViP
With the interval time and delay you can make your irrigation strategy.
The interval time is the minimum time between 2 cycles. In this case 30 minutes.
The interval time + delay time is the maximum time between 2 cycles. In this case 30 + 60 = 90 minutes.
So on a very sunny day irrigation is constantly starting on radiation sum, only limited bij the interval time.
If 30 minutes is too long between 2 cycles, then you can lower the interval time.
On a very dark day irrigation is starting on time, so after interval time + delay time.
If 90 minutes is too short or too long, then you can change the delay time.
cycles: number
This is the maximum amount of cycles per day
type of start recipe
This recipe is repeated every day
start- and stop conditions
The options "radiation" and "time" are selected
time: start relative to
time: start time
time: stop relative to
time: stop time
The irrigation is allowed for time between 08:00 am to 17:00 pm.
radiation: start relative to
radiation: start time
radiation: stop relative to
radiation: stop time
The irrigation is allowed for radiation sum between 08:00 am to 18:00 pm.