If several iSii process computers are connected to one control-network, it could occur that information have to be exchanged between the iSii process computers which are not standardized by Cluster couplings in the iSii controls. In these cases a Uni-Switch can be used to share this information a uni cluster coupling is used for this. The calculated Uni-Influence can be shared from a Uni-Switch.

Required software per iSii
-      1 Uni-Switch for each calculated uni-influence. So if 1 influence has to be passed, 1 Uni-Switch must be available in both iSii process computers.

1.      Browse to the floor plan and find the group number of the Uni-Switch that contains the information that must be sent. Write down this group number, in this explanation we assume that the group number is '5'.

2.      Browse to the uni-switch (tab settings) which contains the information which have to be sent and set the 'type of uni-influence' correctly. The calculated uni-influence that is going to be sent is displayed on 'calculated uni-influence'.
 

3.       Browse to the uni-switch (settings tab) on the ISii which receive the information and set the 'type of uni-influence' to 'External input'
 

4.      Browse to the service tab and add the settings 'uni-influence: configuration uni switch (cluster)' and 'uni-influence: group number uni switch (cluster)'.
5.      Set the configuration number from the iSii that send the informatie on 'uni-influence: configuration uni switch (cluster)'.
6.      Set the group number found in step 1 on 'uni-influence: group number uni switch (cluster)'. (in this case 5).
7.      If the Uni-Switch in the two configurations have been set correctly, the status alarm will disappear at 'uni-switch: communication status'.


The retrieved value will be displayed in the receiving iSii as 'Computed uni-influence', which can be used as an influence in various ViP settings.

    • Related Articles

    • NL - Hoe kan ik Uni-schakelingen cluster koppelingen instellen

             NL - Hoe kan ik Uni-schakelingen cluster koppelingen instellen Als er gebruik gemaakt wordt van meerdere iSii procescomputers in 1 regelnetwerk kan het voorkomen dat er informatie tussen de iSii procescomputers moet worden uitgewisseld welke ...
    • EN - How do I switch the computer to daylight saving or standard time?

         Question How do I switch the computer to daylight saving or standard time?  Answer  You decide when the iSii switches over to daylight saving time or standard time. This is not done automatically. It is recommended to program the switch over one ...
    • EN - How to edit/design a visualization (version 2.0)

         Question How to edit/design a visualization?  Answer  1. Click the button "Switch to edit/design mode" 2. The menu bar in the top of the visualization will change. 3. The meaning of the buttons in de menu bar: button meaning Undo last action ...
    • EN - How to work with +Active Air heating

      Question How do I work with +Active Air heating?  Answer  The Active Air heating is used in the following situations: The computed temperature of the heating element is between the minimum and maximum temperature. The pump is switched on when the ...
    • EN - How to switch off the fan in the aspirator box while using sulphur pots

         Question When you are burning sulphur to prevent mildew then it is highly recommanded to switch off the fan of the aspirator box. Otherwise the inside of the aspirator box becomes nasty and the sulfur affects the sensors which drastically shortens ...