Sometimes there is an execution policy that prevents the selected file from executing. This can be changed by opening a command prompt window (CMD) as an administrator and running the following command: powershell -command "& {Set-ExecutionPolicy -ExecutionPolicy Unrestricted -Force}"
Connect your laptop to the head station via 172.18.25.1, with subnet mask 255.255.0.0
Start the Q100UpdateTool
Select for example Q100_Upgrade FWto22 SWto1.1.0.8 (Newest)
Update IIVO to 5.15
Inform the customer that critical processes (e.g. CHP, lighting) must be set to manual operation during the update.
If the device has also been added (see below) then: - LEDs A and E light up continuously - LED B and C flash (transmit/receive)
Add device
License must be adjusted (Max modbus device types)
Add the device
For example, use the IP address of the headstation 172.18.5.1. for 1st Data Connector
Port for 1st modbus terminal 1502, and then continue numbering
Set STATUS to ON
Then Add node, address 1 (address 0 is broadcast)
Then PAR, Far-red and heater status become available
Connect PAR and Far-red to Custom simple/Custom measurement or PAR Crop Measurement 1 and Measurement 2 PAR 0...4000 µmol/m²/s Far-red 0...1000 µmol/m²/s
Q100 updaten naar nieuwste firmware Informeer de klant dat kritische processen (bijvoorbeeld WKK, belichting) handbediend gezet moeten worden tijdens de update. Zie Quick-Start IIVO op PartnerWiki voor update Q100 kopstation: ...
PAR sensor 0-3000 umol Li-190R Een checkkit PAR wordt gebruikt om een PAR sensor te controleren en deze te vergelijken met een nieuwe sensor. Controleer of de ijkfactor correct is ingevuld in de IIVO: Meetbox droge en natte bol Meetbox boven doek ...
Only 1 watchdog per IIVO control station Carefully read the installation manual on the PartnerWiki Check the DIP switches on the timer module Set the blue potentiometer for the time to approx. 35 sec. Click the watchdog relay on the DIN rail in the ...
Have the license adjusted if necessary Add software Give an understandable name Activate the maximum position radar forecast lee and wind side on the CONTROLS tab Add tab and panels for customer On correct dashboard e.g. Home Graph panel for Weather ...
Question I have a PAR sensor in the greenhouse and the software module +PAR. How to use the +PAR module? Answer The iSii + PAR module is optional from version 3.3.3.1 or higher. With this module you can control the PAR value under the (partly) closed ...