IIVO
IIVO - Building visualization background picture
A visualization in IIVO consists of a background picture on which parameters are set. The background picture above can be made with Microsoft Visio or with draw.io. How to use draw.io? Type draw.io into the address line of a browser. Then choose ...
IIVO - Bouwen visualisatie achtergrondplaat
Een visualisatie in IIVO bestaat uit een achtergrondplaat waarop parameters worden gezet. Bovenstaande achtergrondplaat kan gemaakt worden met Microsoft Visio of met draw.io. Hoe gebruik je draw.io? Type draw.io in de adresregel van een browser. Kies ...
IIVO - Switch order of boiler for heat demand and CO2
For example there are 3 boilers. The boilers must be turned on alternately to ensure even wear of the boilers. Daily switch 3 custom simple controls are taking care of the daily switch. Sequence boiler
IIVO - Set up CO2 controls
Configuration Below is a visualization of the CO2 configuration. CO2 can be supplied by the boiler or CHP5 or CHP6. Outside air can be mixed in. Industrial CO2 and liquid CO2 are injected. Connections Climate Required connections in climate: ...
IIVO - Determine base temperature and RTR
1. Complete the excel sheet in the attachment 2. Select D4 to E45 3. Choose Insert and then the dot graph 4. Place the mouse on one of the dots and right click 5. Choose Add Trendline 6. Check "Show comparison in graph" 7. You now have the formula ...
IIVO - Bepaal basistemperatuur en RTR
1. Vul de excel sheet in de bijlage in. Bijvoorbeeld 19,5 invullen met komma, niet met punt. 2. Selecteer D4 t/m E45 3. Kies Invoegen en dan de stippengrafiek 4. Ga met de muis op één van de stippen staan en klik rechts 5. Kies Trendlijn toevoegen 6. ...
IIVO - Warmtewisselaar regelingen inrichten
Configuratie Warmtewisselaars kunnen toegepast worden om warmte aan de buren te leveren. Onderstaand een visualisatie van een mogelijke configuratie. Er wordt warmte geleverd aan Buurman 1 en Buurman 2. Als er vraag en aanbod uitgewisseld moet ...
IIVO - CO2 regelingen inrichten
Configuratie Onderstaand een visualisatie van de CO2 configuratie. CO2 kan geleverd worden door de ketel of WKK5 of WKK6. Buitenlucht kan bijgemengd worden. OCAP CO2 en vloeibare CO2 worden geïnjecteerd. Koppelingen Klimaat Benodigde koppelingen in ...
IIVO - Watchdog relais Finder 86 - NL
Slechts 1 watchdog per IIVO regelstation Lees nauwkeurig de installatie handleiding op de PartnerWiki Controleer de DIP switches op de timer module Zet de blauwe potentiometer voor de tijd op ca. 35 sec. Klik het watchdog-relais op de DIN-rail in het ...
IIVO - Troubleshooting Aspirator box
Greenhouse temperature is not measured properly with a dry/wet bulb aspirator box At a distance (online) Carefully read the installation manual on the PartnerWiki Check whether real time values are received in I/O CONFIGURATION Check whether the ...
IIVO - Set Weather Forecast & Radar Forecast
Have the license adjusted if necessary Add software Give an understandable name Activate the maximum position radar forecast lee and wind side on the CONTROLS tab Add tab and panels for customer On correct dashboard e.g. Home Graph panel for Weather ...
IIVO - Watchdog relais Finder 86
Only 1 watchdog per IIVO control station Carefully read the installation manual on the PartnerWiki Check the DIP switches on the timer module Set the blue potentiometer for the time to approx. 35 sec. Click the watchdog relay on the DIN rail in the ...
Silal - How to fix a sensor problem
As shown in the screenshot below, the greenhouse temperature measurement is -10 °C and the RH measurement is 0%. The graph shows that the measurements have been wrong for a long time. 1. Open the Dataconnector panel 2. The green led's of the power ...
IIVO Aquabalance onderhoud
De Aquabalance is een hoogwaardig instrument en door tijdig onderhoud en controle bent u verzekerd van een correcte werking. Lees eerst de procedure geheel door en ga zorgvuldig te werk. Laat de Aquabalance niet vallen en vermijd harde schokken. De ...
IIVO Sensor onderhoud
PAR sensor 0-3000 umol Li-190R Een checkkit PAR wordt gebruikt om een PAR sensor te controleren en deze te vergelijken met een nieuwe sensor. Controleer of de ijkfactor correct is ingevuld in de IIVO: Meetbox droge en natte bol Meetbox boven doek ...
IIVO Water supply stategy
Irrigation based on time is allowed between 10:00 and 16:00 From 10:08 to 13:43, the maximum time between drip rounds is 01:30 From 13:43 to 14:57, the maximum time between drip rounds is 02:00 Irrigation based on radiation is allowed between 07:38 ...